2013/10/31 · I have the same boiler, remember it wont condense properly (and be its most efficient) if your return flow temp is above 60 ish, (google will confirm) currently I`m running it for CH at 58 I think, but when it gets really cold will increase that as performance is obviously less. Trust. 29 …
Read MoreRecommended night-time temperature is 16-19 C Turning down your thermostat by just 1°C can save you £80 to £85 a year, according to the Energy Saving Trust. But it's worth keeping in mind that babies should sleep in a room with a temperature between 16°C and 20°C, according to the Lullaby Trust.
Read More2021/3/26 · To maximise efficiency, we recommend setting your radiator dial to 75 degrees and your hot water to 60 degrees. Once you've got your boiler running at the optimal temperature, you'll want to set the timer for when you need heating the most. With a combi boiler, hot water is on demand.
Read More2021/9/9 · Thus, a condensing boiler will be more efficient if it is coupled with water-based underfloor heating with the flow temperature of 40 to 45 degrees Celsius. Since there is no recommended minimum temperature for the coolant, a boiler that is connected to an underfloor heating system can work without special temperature-lowering devices.
Read MoreMaximum boiler flow temperature is often set to 80oC (176oF) to avoid "burned dust" and accidentally injures on people when touching heaters. Outside design temperature depends on the actual location. Boiler Flow Temperature (oC) Minimum Outside Design Temperature. (oC) Outside Temperature …
Read MoreThe maximum temperature that we recommend you set your radiator output to is 80 °C. If you have a conventional boiler system, your water cylinder will have its own thermostat. This is usually fitted on the side of the tank. You should set the temperature between 60 and 65 °C but for maximum efficiency, it should be set to around 60 °C.
Read MoreFlow & Boiler Power Requirements You should note that the higher the boiler flow rates are, & the larger the rise in temperature needed from the mains water, the more powerful the boiler needs to be in order to cope with heating a faster flow of water.
Read MoreMaximum boiler flow temperature is often set to 80oC (176oF) to avoid "burned dust" and accidentally injures on people when touching heaters. Outside design temperature depends on the actual location. Boiler Flow Temperature (oC) Minimum Outside Design Temperature. (oC) Outside Temperature …
Read More2017/2/25 · Your boiler reheats this buffer on on/off temperature thresholds so that each heating chunk is a sensible amount - - say 30-40 mins of continuous output at its optimum output setting to lift the buffer to 40°C say. Your UFH manifold / pump / mixer then blends this buffered hot water into the slab at ambient + 6-8°C if you want to sustain +4
Read More2005/5/21 · Optimum boiler flow temp for condensing boiler ! Discussion in 'Plumbers' Talk' started by monkey wrench, May 19, 2005. monkey wrench New Member What is the optimum flow temperature of the water leaving a condensing boiler in order to keep the boiler in
Read MoreThis would normally be set to about 50 degrees C and is designed to turn the boiler OFF when the cylinder reaches this temperature, in order to save fuel. The complexity arises from the fact that the boiler control needs to be set to a higher value than the hot water cylinder thermostat, or the boiler water will never raise the cylinder water to the setting on the cylinder thermostat.
Read MoreIt can vary from 70 degrees (room temperature) up to 180F if you need it. The boiler is maintained at a different scale, the 180 to 140 range because you have to. Oh well. But the radiator will "sip" this water and return and equal amount back to the boiler. The boiler water not sent out keeps the boiler warm.
Read More2020/5/29 · Any water that is not required will be sent back to the boiler to be re-heated to 82 C. The temperature range for the thermostatic RWC mixing valve is from 35 C to 65 C. Between the mixing valve and the flow manifold an underfloor heating pump must always be fitted to provide circulated water for the heating loops.
Read More2008/8/4 · When applied to integrated condensing boiler systems, variable primary configuration automatically modulates flow rate to match building load while maintaining minimum flow rate across the boiler. By reducing flow rate and supply temperature, terminal control devices stay open, reducing system pressure drop and wasted electrical input.